| Product characteristics |
| Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
| Measuring range |
|
| Process connection |
threaded connection G 1/4 internal thread |
| Application |
| Special feature |
Gold-plated contacts |
| Application |
for industrial applications |
| Media |
liquids and gases |
| Medium temperature [°C] |
-25…80 |
| Min. bursting pressure [mbar] |
30000 |
| Pressure rating [mbar] |
10000 |
| Type of pressure |
relative pressure |
| Electrical data |
| Operating voltage [V] |
18…36 DC; (to SELV/PELV) |
| Current consumption [mA] |
< 50 |
| Min. insulation resistance [MΩ] |
100; (500 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Overvoltage protection |
yes; (< 40 V) |
| Power-on delay time [s] |
0.3 |
| Integrated watchdog |
yes |
| Inputs / outputs |
| Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
| Outputs |
| Total number of outputs |
2 |
| Output signal |
switching signal; analogue signal; (configurable) |
| Electrical design |
PNP |
| Number of digital outputs |
1 |
| Output function |
normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC [V] |
2 |
| Permanent current rating of switching output DC [mA] |
250 |
| Switching frequency DC [Hz] |
< 170 |
| Number of analogue outputs |
1 |
| Analogue current output [mA] |
4…20 |
| Max. load [Ω] |
500 |
| Analogue voltage output [V] |
0…10 |
| Min. load resistance [Ω] |
2000 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
pulsed |
| Measuring/setting range |
| Measuring range |
|
| Set point SP [mbar] |
10…1000 |
| Reset point rP [mbar] |
5…995 |
| In steps of [mbar] |
5 |
| Factory setting |
|
SP1 = 250 mbar |
rP1 = 230 mbar |
|
| Accuracy / deviations |
| Switch point accuracy [% of the span] |
< ± 0,5 |
| Repeatability [% of the span] |
< ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation [% of the span] |
< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Hysteresis deviation [% of the span] |
< ± 0,25 |
| Long-term stability [% of the span] |
< ± 0,05; (per 6 months) |
| Temperature coefficient zero point [% of the span / 10 K] |
0,2; (-20…80 °C) |
| Temperature coefficient span [% of the span / 10 K] |
0,2; (-20…80 °C) |
| Response times |
| Delay time programmable dS, dr [s] |
0; 0,2…50 |
| Max. response time analogue output [ms] |
3 |
| Software / programming |
| Parameter setting options |
hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output |
| Operating conditions |
| Ambient temperature [°C] |
-20…80 |
| Storage temperature [°C] |
-40…100 |
| Protection |
IP 65 |
| Tests / approvals |
| EMC |
| EN 61000-4-2 ESD |
4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated |
10 V/m |
| EN 61000-4-4 Burst |
2 kV |
| EN 61000-4-5 Surge |
0,5/1 kV |
| EN 61000-4-6 HF conducted |
10 V |
|
| Shock resistance |
| DIN IEC 68-2-27 |
50 g (11 ms) |
|
| Vibration resistance |
| DIN IEC 68-2-6 |
20 g (10…2000 Hz) |
|
| MTTF [years] |
213 |
| Mechanical data |
| Weight [g] |
261 |
| Materials |
stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; PTFE |
| Materials (wetted parts) |
stainless steel (1.4305 / 303); ceramics; FKM |
| Min. pressure cycles |
100 million |
| Process connection |
threaded connection G 1/4 internal thread |
| Displays / operating elements |
| Display |
| Display unit |
4 x LED, green |
| switching status |
LED, yellow |
| function display |
alphanumeric display, 4-digit |
| measured values |
alphanumeric display, 4-digit |
|
| Display unit |
mbar; kPa; psi; inHg |
| Remarks |
| Pack quantity |
1 pcs. |
| Electrical connection |
| Connection |
Connector: 1 x M12; Contacts: gold-plated |